Annotation
A methodology is proposed for target strength measurements by using UltraWide Band (UWB) signals. Using high stability clocks for synchronization of the transmitter and receiver? Accurate time-of-flight measurements can be made between transmitters and receivers via direct and reflected acoustic paths. Target strength is calculated by comparing the correlation of the signals received from the direct path and reflected paths, with reference signals. This technique enables target strength measurements in negative SNR environments. The implementation of this methodology is described.
Received: 2017 July 11
Approved: 2017 October 17
PACS:
43.30.+m Underwater sound
© 2016 Publisher M.V.Lomonosov Moscow State University
Authors
Yu. N. Popov, N. M. Lisenkov
$^1$Krylov State Research Centre
$^1$Krylov State Research Centre